Eclipse Burner TJ0500

  • Gas Burner: Eclipse Burner TJ0500
  • Model: Eclipse ThermJet Burners TJ0500
  • Capacity: 156,958Btu/h = 1260,000Kcal/h = 1465kW/h
  • Inlet Gas Pressure: 3.2kPa = 32mBar = 14"WC
  • Sensor: Flame Rod or Uv S-ensor
  • Brand: Eclipse Kato Burner Co.,Ltd.Eclipse ThermJet Burners TJ0500 Specifications
  • Made in U.S.A 100%
  • Applications: Tempering Furnaces, Hardening Furnaces, Reheating Furnaces, Fluidized Bed Dryers, Thermal Oxidizers, Non-Ferrous Melting,Ladle/Tundish, Glass Lehrs Environmental Applications,Preheated Air
Eclipse Burner TJ0500(117kW)
  • Eclipse Burner TJ0500 (1)
  • Eclipse Burner TJ0500 (2)
  • Eclipse Burner TJ0500 (3)
  • Eclipse Burner TJ0500 (4)
  • Eclipse Burner TJ0500 (5)
  • Eclipse Burner TJ0500 (6)
  • Eclipse Burner TJ0500 (7)
  • Eclipse Burner TJ0500 (8)
  • Eclipse Burner TJ0500 (9)
  • Eclipse Burner TJ0500 (10)
  • Eclipse Burner TJ0500 (11)
  • Eclipse Burner TJ0500 (12)
Related Links:
  1. Eclipse Burner TJ0015
    Origin: U.S.A 100%
    Capacity:150,000Btu/h=37800Kcal/h
    Eclipse Burner TJ0015-44kw
  2. Eclipse Burner TJ0025
    Origin: U.S.A 100%
    Capacity:250,000Btu/h=63,000Kcal/h
    Eclipse Burner TJ0025-73kw
  3. Eclipse Burner TJ0040
    Origin: U.S.A 100%
    Capacity:400,000Btu/h=100,800Kcal/h
    Eclipse Burner TJ0040-117kw
  4. Eclipse Burner TJ0015
    Origin: U.S.A 100%
    Capacity:500,000Btu/h=126,000Kcal/h
    Eclipse Burner TJ0050-146kw
  5. Eclipse Burner TJ0075
    Origin: U.S.A 100%
    Capacity:750,000Btu/h=189,000Kcal/h
    Eclipse Burner TJ0075-220kw
  6. Eclipse Burner TJ0100
    Origin: U.S.A 100%
    Capacity:1000,000Btu/h=252,000Kcal/h
    Eclipse Burner TJ0100-293kw
  7. Eclipse Burner TJ0150
    Origin: U.S.A 100%
    Capacity:1500,000Btu/h=378,000Kcal/h
    Eclipse Burner TJ0150-440kw
  8. Eclipse Burner TJ0200
    Origin: U.S.A 100%
    Capacity:2000,000Btu/h=504000Kcal/h
    Eclipse Burner TJ0200-586kw
  9. Eclipse Burner TJ0300
    Origin: U.S.A 100%
    Capacity:156,958Btu/h=756,000Kcal/h
    Eclipse Burner TJ0300-879kw
  10. Eclipse Butterfly Valve 4BV-AB
    Origin: U.S.A 100%
    Pressure: 5Psi Inlet Size: 1" DN25
    Eclipse Butterfly Valve 4BV-AB
  11. Eclipse Butterfly Valve 10BV-A
    Origin: U.S.A 100%
    Pressure:350mbar Inlet Size: 2.1/2"
    Eclipse Butterfly Valve 10BVM-A
  12. Eclipse Butterfly Valve 12BVM-A
    Origin: U.S.A 100%
    Pressure:350mbar Inlet Size: 3"
    Eclipse Butterfly Valve 12BVM-A
  13. Spark Rod Eclipse10019728
    Origin: U.S.A 100%
    Inlet Size: M14
    Spark Rod Eclipse10019728